From inside (document excerpt):
58MXA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Installation, Start-Up, and Operating Instructions For Sizes 040–120, Series 131 ® ama CANADIAN GAS ASSOCIATION A PP R O VED R A93040 NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. Index Page DIMENSIONAL DRAWING 2 SAFETY CONSIDERATIONS .3 Clearances to Combustibles 3 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS 3-4 INTRODUCTION 4 APPLICATIONS 4-11 General 4 Upflow Applications 4-6 Downflow Applications .7-8 Horizontal Left (Supply-Air Discharge) Applications .8-9 Horizontal Right (Supply-Air Discharge) Applications .9-11 LOCATION 11-12 General .11-12 Furnace Location Relative to Cooling Equipment 12 Hazardous Locations .12 INSTALLATION 13-16 Leveling Legs (If Desired) .13 Installation On a Concrete Slab .13 Installation On a Combustible Floor (Downflow Applications) 13-14 Installation In Horizontal Applications 14 Filter Arrangement 15 Bottom Closure Panel .15 Gas Piping .16 ELECTRICAL CONNECTIONS .16-20 115-v Wiring 16-17 24-v Wiring .19 Accessories 20 DIRECT VENTING .20-28 Removal of Existing Furnaces from Common Vent Systems .20 Combustion-Air and Vent Piping .20-26 Concentric Vent and Combustion-Air Termination Kit Installation 26-28 Multiventing and Vent Termination .28 CONDENSATE DRAIN 28-30 General 28 Application 30 Condensate Drain Protection 30 As an ENERGY STARSM Partner, Carrier Corporation has determined that this product meets the ENERGY STAR guidelines for energy efficiency.
CERTIFICATION OF MANUFACTURING SITE AIRFLOW UPFLOW HORIZONTAL LEFT DOWNFLOW AIRFLOW HORIZONTAL RIGHT AIRFLOW AIRFLOW Fig. 1–Multipoise Orientations A93041 SEQUENCE OF OPERATION 30-32 Heating Mode 30-31 Cooling Mode .31 Continuous Blower Mode .31 Heat Pump Mode 31 Component Test .31-32 START-UP PROCEDURES 32-37 General 32 Prime Condensate Trap With Water 32 Purge Gas Lines 33 Adjustments .33-37 Set Gas Input Rate 33-36 Set Temperature Rise 37 Adjust Blower Off Delay (Heat Mode) .37 Set Thermostat Heat Anticipator 37 CHECK SAFETY CONTROLS 38 Check Primary Limit Control .38 Check Pressure Switch .38 CHECKLIST .38-39 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 565-975 Printed in U.S.A. Form 58MXA-6SI Pg 1 5-96 Replaces: 58MXA-5SI Tab 6a 8a 26 15/16 ” 26 15/16 ” AIRFLOW 26 1/4 ” 22 5/16 ” 13/16 ” 9/16 ” TYP 28 1/2 ” 26 1/4 ” A 13/16 ” 24 1/2 ” D OUTLET 2-IN. COMBUSTIONAIR CONN DIA GAS CONN 7/8-IN. 1/2-IN. 22 19 ” OUTLET CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL LEFT) 7/8-IN. 5/8 ” 5/16 ” 2-IN. COMBUSTIONAIR CONN 13/16 ” DIA GAS CONN 1/2-IN. DIA POWER CONN CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL RIGHT) OR ALTERNATE 1/2-IN. DIA GAS CONN 5/16 ” 2-IN. VENT CONN DIA POWER CONN 1/2-IN. 7/8-IN. DIA THERMOSTAT ENTRY 22 11/16