From inside (document excerpt):
SPLIT-TYPE AIR CONDITIONER CONTENTS 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR INSTALLATION MANUAL Model SAFETY . 2 2. INSTALLATION DIAGRAM & ACCESSORIES 2 MXZ-A26/32WV utilized HFC 3. SELECTING THE INSTALLATION LOCATION . 3 4. OUTDOOR UNIT INSTALLATION . 4 5. INDOOR/OUTDOOR UNITS CONNECTION FINISHING AND TEST RUN . 6 R410A This Installation Manual describes only for the outdoor unit and the connected indoor unit of MSH series.
If the connected indoor unit is MSH, MSZ, MCFH, SLZ and SEZ series, refer to the Installation Manual for MSH, MSZ, MCFH, SLZ and SEZ series for the information other than outdoor unit. IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS OF AUSTRALIAN STANDARD AS 3000 S.A.A. WIRING RULES, THE ELECTRICAL WIRING REQUIRED BETWEEN THE INDOOR AND OUTDOOR UNITS MUST BE INSTALLED BY A LICENCED ELECTRICAL CONTRACTOR. FOR INSTALLER 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY · Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY ” before installing the air conditioner. · Be sure to observe the cautions specified here as they include important items related to safety. · The indications and meanings are as follows. WARNING: Could lead to death, serious injury, etc. CAUTION: Could lead to serious injury in particular environments when operated incorrectly. · After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS in a handy place on the customer’s site. 2. INSTALLATION DIAGRAM & ACCESSORIES Before installation This installation manual is only for the outdoor unit installation. In installing the indoor units, refer to the installation manual attached to each indoor unit. Any structual alternations necessary for the installation must comply with the local building code requirements. WARNING I Do not install the unit by yourself (customer). Incomplete installation could cause injury due to fire, electric shock, the unit falling or leakage of water. Consult the dealer from whom you purchased the unit or special installer. I Install the unit securely in a place which can bear the weight of the unit. When installed in an insufficient strong place, the unit could fall causing injury. I Use the specified wires to connect the indoor and outdoor units securely and attach the wires firmly to the terminal block connecting sections so the stress of the wires is not applied to the sections. Incomplete connecting and fixing could cause fire. I Do not use intermediate connection of the power cord or the extension cord and do not connect many devices to one AC outlet. It could cause a fire or an electric shock due to defective contact, defective insulation, exceeding the permissible current, etc. I Check that the refrigerant gas due not leak after installation has completed. If refrigerant gas leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated. I Perform the installation securely referring to the installation manual. Incomplete installation could cause a personal injury due to fire, electric shock, the unit falling or leakage of water. I Perform electrical work according to the installation manual and be sure to use an exclusive circuit. If the capacity of the power circuit is insufficient or there is insufficient electrical work, it could result in a fire or an electric shock. I Attach the electrical cover to the indoor unit and the service panel to the outdoor unit securely. If the electrical cover in the indoor unit and/or the service panel in the outdoor unit are not attached securely, it could result in a fire or an electric shock due to dust water, etc.